Our Clients

3MG – 1200°C – SH Muffle Furnace

$2,180

What’s New in 2025
Mobile Fume Extractor
Mobile Fume Extractor/Hood
  • Harmful gas & fume removal protects laboratory air quality
  • Three-stage filtration system. Pre-filter, HEPA filter and VOC filter
  • Adjustable airflow. 10 levels of air intake and exhaust volume adjustment
  • Ductless operation
  • (Optional) Testo 300 Combustion Gas Analyzer for Monitoring Oxygen-free atmosphere inside the chamber or tube and measure combustion gas and synthetic gas components – Contact us for available options
  • (Optional) Laboratory Gas-Drying Unit by Drierite™ with Connector
  • (Optional) Quartz Shelf Designed to Maximize Available Space in the Chamber
  • General muffle furnace with swing door
  • Recommended ideal running temperature is below 1000°C
  • Heating from 4 sides and excellent temperature uniformity (+/-2.5%)
  • Excellent outgassing thanks to the exhaust air outlet on the head of chamber, i.e plastic polymer
  • Double housing and low surface temperature (29~30°C at 800°C)
  • SSR operation and PID control provides low noise operation and precise temp control (+/-1°C)
  • Inert gas atmosphere available with optional ball type flow meter
  • 30 steps FC-570 programmable controller available with option
SKU: SH-FU-3MG Categories: , ,
    • $0
    • $0
    • $0
    • $0

  • Add Portable Fume Hood ($1,730 + $250 Shipping)

    • Harmful gas & fume removal protects laboratory air quality
    • Flexible arm. Precise positioning to capture fumes directly at the source
    • Three-stage filtration system. Pre-filter, HEPA filter and VOC (volatile organic compounds) filter
    • Adjustable airflow. 10 levels of air intake and exhaust volume adjustment
    • $0

Options amount
$0

Description

If you conduct thermal treatments at standard temperatures, then don’t overpay for a standard design!

SH Scientific’s MG line of standard muffle furnaces are capable of up to max 1200°C, with an ideal operating temperature of below 1000°C. This line is made with cost-conscious facilities, but in need for slightly higher maximum temperature limit of 1200°C compared, delivering rock-solid performance without costly frills or superfluous certifications.

  • Rapid heating: Our MG furnaces reach 800°C in less than 40 minutes.
  • Multiple sizes available: Choose among several standard capacity options, and pay for no more and no less than you need.

SH Scientific muffle furnaces are used for a wide range of thermal treatments and experiments, including:

  • Ashing
  • Calcination
  • Reduction
  • Oxidation
  • Dissociation
  • Sintering
  • Pyrolysis
  • Reaction
  • Hardening and tempering
  • Melting
  • Thermocouple calibration
  • Annealing
  • Stress relieving

…among many more.
Need something we haven’t listed here? Reach out to share your requirements and talk through more customized offerings.

Additional information

Weight 113 lbs
Dimensions 25 × 21 × 31 in
Model SH-FU-3MG
Max temperature 1200℃
Continuous running temperature 1000℃
Chamber volume 3liters
Controller Digital PID controller
Sensor K type
Heater 1.4kW
Heating element Kanthal A-1
Insulation
Ceramic
Power supply
110V, 50/60Hz, 1p, 12A
220V, 50/60Hz, 1p, 6A
Net weight 34kg
Chamber size 130x250x90mm
External size 370x510x570mm
Muffle Furnace Customer Photo
Muffle Furnace Customer Photo 2
shscientific_muffle_furnace_27liters_1200c_sh_fu_mg_series
previous arrow
previous arrow
next arrow
next arrow
shscientific_muffle_furnace_27liters_1200c_sh_fu_mg_series
Muffle Furnace Customer Photo
Muffle Furnace Customer Photo 2
shscientific_muffle_furnace_sh-fu-3mg_gas_flow_meter_programmable_controller_2
shscientific_muffle_furnace_sh-fu-3mg_gas_flow_meter_programmable_controller_4
shscientific_muffle_furnace_sh-fu-3mg_gas_flow_meter_programmable_controller_6
shscientific_muffle_furnace_sh-fu-3mg_gas_flow_meter_programmable_controller_5
shscientific_muffle_furnace_sh-fu-3mg_gas_flow_meter_programmable_controller_9
shscientific_vacuum_muffle_furnace_sh-fu-10mgv_featured_with_bpr_back_pressure_regulator-2
shscientific_vacuum_muffle_furnace_sh-fu-10mgv_featured_with_bpr_back_pressure_regulator-3
shscientific_vacuum_muffle_furnace_sh-fu-10mgv_featured_with_bpr_back_pressure_regulator-6
shscientific_vacuum_muffle_furnace_sh-fu-10mgv_featured_with_bpr_back_pressure_regulator-8
shscientific_vacuum_muffle_furnace_sh-fu-10mgv_featured_with_bpr_back_pressure_regulator-10
shscientific_vacuum_muffle_furnace_sh-fu-10mgv_featured_with_bpr_back_pressure_regulator-12
shscientific_vacuum_muffle_furnace_sh-fu-10mgv_featured_with_bpr_back_pressure_regulator-5
shscientific_vacuum_muffle_furnace_sh-fu-10mgv_featured_with_bpr_back_pressure_regulator-9
sh_scientific_1200c_muffle_furnace_14liters_sh_fu_14mg_customer_photo_1_heattreatingA2toolsteel
sh_scientific_1200c_muffle_furnace_14liters_sh_fu_14mg_customer_photo_2_heattreatingA2toolsteel
sh_scientific_1200c_muffle_furnace_14liters_sh_fu_14mg_customer_photo_3_heattreatingA2toolsteel
sh_scientific_muffle_furnace_sh-fu-3mge-customer-3
previous arrow
next arrow

Reviews

There are no reviews yet.


Only logged in customers who have purchased this product may leave a review.

Content missing